Cable Splicing Materials
Cable splicing process is required for every electric submersible pumping unit since the motor lead extension cable has to be used to go from the motor and extended long enough to clear the pump due to the small clearance between the pump and the inside of the casing. Cable joints have to be made between the motor lead extension cables to the flat or round configuration power cables.
OriSun splicing materials are proven products, covers Hi-tem Teflon Tape, Hi-Modulus Teflon Tape, Teflon TPFE tape, Hi-tem Glass Tape and Ni-compress
Hi-tem Teflon FEP Tape
Items |
Unit |
Standard |
Standard |
Standard |
Thickness |
mm |
0.125±0.010 |
0.100±0.010 |
0.085±0.010 |
FEP Film Thickness |
mm |
0.089 |
0.08 |
0.05 |
Width |
mm |
15.0 / 25.0 / 25.4 / ±1.0 |
6 – 300 (Available width for option) |
Length |
m/roll |
10±0.2 |
Breaking Strength |
N/25mm |
|
≥20.0 |
≥13.0 |
Elongation |
% |
≥300 |
≥280 |
≥250 |
Dielectric Strength |
KV |
≥8.4 |
≥6 |
≥4 |
Adhesion to Steel |
N/25mm |
≥12 |
≥12 |
≥12 |
Adhesion to F46 |
N/25mm |
≥10 |
≥10 |
≥10 |
Operating Temperature |
℃ |
204 |
The tape shall have a one year shelf life when stored in a controlled environment of 21 ℃, |
with a relative humidity of 40 to 50 percent. | |